Key Indicators Of Architectural Window Films

Jul 20, 2024

Leave a message

According to the evaluation basis recognized by the international film industry, the evaluation practice of the quality index of architectural film
The key indicators are: solar heat gain coefficient SHGC (smaller the better), total solar energy barrier rate TSER (larger is better), ultraviolet blocking rate, visible light transmittance.


The false indicator is: infrared blocking rate
This is because the principle of building membrane insulation is to reflect a part of the heat, isolate a part of the heat, and absorb a part of the heat. When sunlight shines, 49% of the main source of energy is infrared, and about 50% is visible light. Infrared blocking is only a part of the thermal blocking of too hot radiation, and many manufacturers selectively give the infrared blocking rate of a certain band, rather than the infrared blocking rate of the whole band, there is a common phenomenon of parameter fraud, which cannot be used as the main reference index. In addition, the infrared barrier rate does not include the part of the heat absorbed by the membrane, and the heat absorption part is also one of the important factors for the real thermal insulation effect. This indicator is a commercial eye-catching hype that has little real value.


Solar heat gain coefficient SHGC (also known as solar total transmittance, heat gain factor, g value, known as the occlusion coefficient in China's GB/T2680, often abbreviated as Se or Sc): refers to the ratio of solar radiation energy entering the room through the glass under the same conditions (including both the direct penetrating part and the heat released after absorption) and the solar heat entering the room through the same size but without the glass opening. The smaller the shading coefficient, the better the performance of blocking the sun's heat from radiating indoors. That is, the lower the value, the better the performance of the membrane.


Solar Barrier Rate (TSER): A metric that actually reflects the true data of the film's thermal insulation capacity. Because it calculates the entire solar spectrum range. (Infrared light makes up only 49% of the solar spectrum.) It also contains the energy that is absorbed. Therefore, such as Energy Star and other institutions and the United States Door and Window Evaluation Committee, the Canada government, etc., only use SHGC/TSER data as a criterion rather than infrared barrier rate. The higher the number, the better.


Ultraviolet Blocking Rate: Refers to the percentage of ultraviolet rays (300-380nm) in incident sunlight that are blocked by the window glazing system, usually expressed as a percentage. Ultraviolet radiation causes the skin to produce a large number of free radicals, which leads to peroxidation of cell membranes, causing melanocytes to produce more melanin and distribute it up to the stratum corneum of the epidermis, causing dark spots. Causes wrinkles, aging, sagging and dark spots on the skin. The higher the number, the better.